syzbot


KCSAN: data-race in __lru_add_drain_all / folio_add_lru

Status: moderation: reported on 2021/12/14 17:42
Subsystems: mm
[Documentation on labels]
Reported-by: syzbot+d676f4fcc6452f55d1d0@syzkaller.appspotmail.com
First crash: 1349d, last: 22h14m

Sample crash report:
EXT4-fs (loop1): unmounting filesystem 00000000-0000-0000-0000-000000000000.
==================================================================
BUG: KCSAN: data-race in __lru_add_drain_all / folio_add_lru

read-write to 0xffff888237d25e68 of 1 bytes by task 6521 on cpu 1:
 folio_batch_add include/linux/pagevec.h:77 [inline]
 __folio_batch_add_and_move mm/swap.c:194 [inline]
 folio_add_lru+0xa5/0x1f0 mm/swap.c:505
 folio_add_lru_vma+0x49/0x70 mm/swap.c:524
 wp_page_copy mm/memory.c:3637 [inline]
 do_wp_page+0x132b/0x2400 mm/memory.c:4030
 handle_pte_fault mm/memory.c:6085 [inline]
 __handle_mm_fault mm/memory.c:6212 [inline]
 handle_mm_fault+0x77d/0x2be0 mm/memory.c:6381
 do_user_addr_fault+0x3fe/0x1090 arch/x86/mm/fault.c:1387
 handle_page_fault arch/x86/mm/fault.c:1476 [inline]
 exc_page_fault+0x62/0xa0 arch/x86/mm/fault.c:1532
 asm_exc_page_fault+0x26/0x30 arch/x86/include/asm/idtentry.h:623
 __put_user_nocheck_4+0x3/0x10 arch/x86/lib/putuser.S:97
 ____sys_recvmsg+0x1a1/0x280 net/socket.c:2799
 ___sys_recvmsg+0x11f/0x370 net/socket.c:2828
 do_recvmmsg+0x1ef/0x540 net/socket.c:2923
 __sys_recvmmsg net/socket.c:2997 [inline]
 __do_sys_recvmmsg net/socket.c:3020 [inline]
 __se_sys_recvmmsg net/socket.c:3013 [inline]
 __x64_sys_recvmmsg+0xe5/0x170 net/socket.c:3013
 x64_sys_call+0x1c6a/0x2fb0 arch/x86/include/generated/asm/syscalls_64.h:300
 do_syscall_x64 arch/x86/entry/syscall_64.c:63 [inline]
 do_syscall_64+0xd2/0x200 arch/x86/entry/syscall_64.c:94
 entry_SYSCALL_64_after_hwframe+0x77/0x7f

read to 0xffff888237d25e68 of 1 bytes by task 3314 on cpu 0:
 folio_batch_count include/linux/pagevec.h:56 [inline]
 cpu_needs_drain mm/swap.c:773 [inline]
 __lru_add_drain_all+0x12b/0x3f0 mm/swap.c:867
 lru_add_drain_all+0x10/0x20 mm/swap.c:883
 invalidate_bdev+0x47/0x70 block/bdev.c:101
 ext4_put_super+0x624/0x7d0 fs/ext4/super.c:1339
 generic_shutdown_super+0xe6/0x210 fs/super.c:643
 kill_block_super+0x2a/0x70 fs/super.c:1755
 ext4_kill_sb+0x42/0x80 fs/ext4/super.c:7391
 deactivate_locked_super+0x75/0x1c0 fs/super.c:474
 deactivate_super+0x97/0xa0 fs/super.c:507
 cleanup_mnt+0x269/0x2e0 fs/namespace.c:1417
 __cleanup_mnt+0x19/0x20 fs/namespace.c:1424
 task_work_run+0x131/0x1a0 kernel/task_work.c:227
 resume_user_mode_work include/linux/resume_user_mode.h:50 [inline]
 exit_to_user_mode_loop+0xe4/0x100 kernel/entry/common.c:114
 exit_to_user_mode_prepare include/linux/entry-common.h:330 [inline]
 syscall_exit_to_user_mode_work include/linux/entry-common.h:414 [inline]
 syscall_exit_to_user_mode include/linux/entry-common.h:449 [inline]
 do_syscall_64+0x1d6/0x200 arch/x86/entry/syscall_64.c:100
 entry_SYSCALL_64_after_hwframe+0x77/0x7f

value changed: 0x01 -> 0x02

Reported by Kernel Concurrency Sanitizer on:
CPU: 0 UID: 0 PID: 3314 Comm: syz-executor Not tainted 6.16.0-rc5-syzkaller-00266-g3f31a806a62e #0 PREEMPT(voluntary) 
Hardware name: Google Google Compute Engine/Google Compute Engine, BIOS Google 05/07/2025
==================================================================

Crashes (1398):
Time Kernel Commit Syzkaller Config Log Report Syz repro C repro VM info Assets (help?) Manager Title
2025/07/13 01:13 upstream 3f31a806a62e 3cda49cf .config console log report info [disk image] [vmlinux] [kernel image] ci2-upstream-kcsan-gce KCSAN: data-race in __lru_add_drain_all / folio_add_lru
2025/07/12 15:53 upstream 379f604cc3dc 3cda49cf .config console log report info [disk image] [vmlinux] [kernel image] ci2-upstream-kcsan-gce KCSAN: data-race in __lru_add_drain_all / folio_add_lru
2025/07/11 19:57 upstream 40f92e79b0aa 3cda49cf .config console log report info [disk image] [vmlinux] [kernel image] ci2-upstream-kcsan-gce KCSAN: data-race in __lru_add_drain_all / folio_add_lru
2025/07/10 17:00 upstream 8c2e52ebbe88 3cda49cf .config console log report info [disk image] [vmlinux] [kernel image] ci2-upstream-kcsan-gce KCSAN: data-race in __lru_add_drain_all / folio_add_lru
2025/07/10 05:52 upstream 8c2e52ebbe88 956bd956 .config console log report info [disk image] [vmlinux] [kernel image] ci2-upstream-kcsan-gce KCSAN: data-race in __lru_add_drain_all / folio_add_lru
2025/07/09 22:45 upstream 8c2e52ebbe88 f4e5e155 .config console log report info [disk image] [vmlinux] [kernel image] ci2-upstream-kcsan-gce KCSAN: data-race in __lru_add_drain_all / folio_add_lru
2025/07/09 16:20 upstream 733923397fd9 f4e5e155 .config console log report info [disk image] [vmlinux] [kernel image] ci2-upstream-kcsan-gce KCSAN: data-race in __lru_add_drain_all / folio_add_lru
2025/07/08 16:55 upstream d006330be3f7 4d9fdfa4 .config console log report info [disk image] [vmlinux] [kernel image] ci2-upstream-kcsan-gce KCSAN: data-race in __lru_add_drain_all / folio_add_lru
2025/07/07 01:39 upstream d7b8f8e20813 4f67c4ae .config console log report info [disk image] [vmlinux] [kernel image] ci2-upstream-kcsan-gce KCSAN: data-race in __lru_add_drain_all / folio_add_lru
2025/07/05 20:40 upstream 05df91921da6 4f67c4ae .config console log report info [disk image] [vmlinux] [kernel image] ci2-upstream-kcsan-gce KCSAN: data-race in __lru_add_drain_all / folio_add_lru
2025/07/05 09:21 upstream a79a588fc176 4f67c4ae .config console log report info [disk image] [vmlinux] [kernel image] ci2-upstream-kcsan-gce KCSAN: data-race in __lru_add_drain_all / folio_add_lru
2025/07/05 05:31 upstream a79a588fc176 d869b261 .config console log report info [disk image] [vmlinux] [kernel image] ci2-upstream-kcsan-gce KCSAN: data-race in __lru_add_drain_all / folio_add_lru
2025/07/04 15:37 upstream 4c06e63b9203 d869b261 .config console log report info [disk image] [vmlinux] [kernel image] ci2-upstream-kcsan-gce KCSAN: data-race in __lru_add_drain_all / folio_add_lru
2025/07/03 22:24 upstream 17bbde2e1716 76ad128c .config console log report info [disk image] [vmlinux] [kernel image] ci2-upstream-kcsan-gce KCSAN: data-race in __lru_add_drain_all / folio_add_lru
2025/07/03 06:45 upstream b4911fb0b060 115ceea7 .config console log report info [disk image] [vmlinux] [kernel image] ci2-upstream-kcsan-gce KCSAN: data-race in __lru_add_drain_all / folio_add_lru
2025/07/02 19:02 upstream b4911fb0b060 bc80e4f0 .config console log report info [disk image] [vmlinux] [kernel image] ci2-upstream-kcsan-gce KCSAN: data-race in __lru_add_drain_all / folio_add_lru
2025/07/02 05:30 upstream 66701750d556 bc80e4f0 .config console log report info [disk image] [vmlinux] [kernel image] ci2-upstream-kcsan-gce KCSAN: data-race in __lru_add_drain_all / folio_add_lru
2025/07/01 15:09 upstream 66701750d556 091a06cd .config console log report info [disk image] [vmlinux] [kernel image] ci2-upstream-kcsan-gce KCSAN: data-race in __lru_add_drain_all / folio_add_lru
2025/07/01 07:04 upstream 66701750d556 6e83b42d .config console log report info [disk image] [vmlinux] [kernel image] ci2-upstream-kcsan-gce KCSAN: data-race in __lru_add_drain_all / folio_add_lru
2025/06/30 18:38 upstream d0b3b7b22dfa 6e83b42d .config console log report info [disk image] [vmlinux] [kernel image] ci2-upstream-kcsan-gce KCSAN: data-race in __lru_add_drain_all / folio_add_lru
2025/06/30 01:51 upstream d0b3b7b22dfa fc9d8ee5 .config console log report info [disk image] [vmlinux] [kernel image] ci2-upstream-kcsan-gce KCSAN: data-race in __lru_add_drain_all / folio_add_lru
2025/06/29 15:29 upstream dfba48a70cb6 fc9d8ee5 .config console log report info [disk image] [vmlinux] [kernel image] ci2-upstream-kcsan-gce KCSAN: data-race in __lru_add_drain_all / folio_add_lru
2025/06/28 23:36 upstream ded779017ad7 fc9d8ee5 .config console log report info [disk image] [vmlinux] [kernel image] ci2-upstream-kcsan-gce KCSAN: data-race in __lru_add_drain_all / folio_add_lru
2025/06/27 07:08 upstream f02769e7f272 803ce19b .config console log report info [disk image] [vmlinux] [kernel image] ci2-upstream-kcsan-gce KCSAN: data-race in __lru_add_drain_all / folio_add_lru
2025/06/26 13:33 upstream ee88bddf7f2f 803ce19b .config console log report info [disk image] [vmlinux] [kernel image] ci2-upstream-kcsan-gce KCSAN: data-race in __lru_add_drain_all / folio_add_lru
2025/06/25 03:45 upstream 7595b66ae9de 26d77996 .config console log report info [disk image] [vmlinux] [kernel image] ci2-upstream-kcsan-gce KCSAN: data-race in __lru_add_drain_all / folio_add_lru
2025/06/24 23:45 upstream 78f4e737a53e 26d77996 .config console log report info [disk image] [vmlinux] [kernel image] ci2-upstream-kcsan-gce KCSAN: data-race in __lru_add_drain_all / folio_add_lru
2025/06/23 22:08 upstream 86731a2a651e e2f27c35 .config console log report info [disk image] [vmlinux] [kernel image] ci2-upstream-kcsan-gce KCSAN: data-race in __lru_add_drain_all / folio_add_lru
2025/06/23 10:06 upstream 86731a2a651e d6cdfb8a .config console log report info [disk image] [vmlinux] [kernel image] ci2-upstream-kcsan-gce KCSAN: data-race in __lru_add_drain_all / folio_add_lru
2025/06/23 03:25 upstream b67ec639010f d6cdfb8a .config console log report info [disk image] [vmlinux] [kernel image] ci2-upstream-kcsan-gce KCSAN: data-race in __lru_add_drain_all / folio_add_lru
2025/06/22 05:42 upstream 739a6c93cc75 d6cdfb8a .config console log report info [disk image] [vmlinux] [kernel image] ci2-upstream-kcsan-gce KCSAN: data-race in __lru_add_drain_all / folio_add_lru
2025/06/21 16:11 upstream 3f75bfff44be d6cdfb8a .config console log report info [disk image] [vmlinux] [kernel image] ci2-upstream-kcsan-gce KCSAN: data-race in __lru_add_drain_all / folio_add_lru
2025/06/21 03:35 upstream 11313e2f7812 d6cdfb8a .config console log report info [disk image] [vmlinux] [kernel image] ci2-upstream-kcsan-gce KCSAN: data-race in __lru_add_drain_all / folio_add_lru
2025/06/20 07:32 upstream 75f5f23f8787 ed3e87f7 .config console log report info [disk image] [vmlinux] [kernel image] ci2-upstream-kcsan-gce KCSAN: data-race in __lru_add_drain_all / folio_add_lru
2025/06/19 21:19 upstream 24770983ccfe ed3e87f7 .config console log report info [disk image] [vmlinux] [kernel image] ci2-upstream-kcsan-gce KCSAN: data-race in __lru_add_drain_all / folio_add_lru
2025/06/19 05:30 upstream fb4d33ab452e ed3e87f7 .config console log report info [disk image] [vmlinux] [kernel image] ci2-upstream-kcsan-gce KCSAN: data-race in __lru_add_drain_all / folio_add_lru
2025/06/18 14:34 upstream 52da431bf03b ed3e87f7 .config console log report info [disk image] [vmlinux] [kernel image] ci2-upstream-kcsan-gce KCSAN: data-race in __lru_add_drain_all / folio_add_lru
2025/06/18 09:13 upstream 52da431bf03b e77fae15 .config console log report info [disk image] [vmlinux] [kernel image] ci2-upstream-kcsan-gce KCSAN: data-race in __lru_add_drain_all / folio_add_lru
2025/06/17 22:35 upstream 4663747812d1 e77fae15 .config console log report info [disk image] [vmlinux] [kernel image] ci2-upstream-kcsan-gce KCSAN: data-race in __lru_add_drain_all / folio_add_lru
2025/06/17 03:23 upstream 9afe652958c3 cfebc887 .config console log report info [disk image] [vmlinux] [kernel image] ci2-upstream-kcsan-gce KCSAN: data-race in __lru_add_drain_all / folio_add_lru
2025/06/15 20:07 upstream 08215f5486ec 5f4b362d .config console log report info [disk image] [vmlinux] [kernel image] ci2-upstream-kcsan-gce KCSAN: data-race in __lru_add_drain_all / folio_add_lru
2025/06/15 06:08 upstream 8c6bc74c7f89 5f4b362d .config console log report info [disk image] [vmlinux] [kernel image] ci2-upstream-kcsan-gce KCSAN: data-race in __lru_add_drain_all / folio_add_lru
2025/06/14 19:34 upstream 4774cfe3543a 5f4b362d .config console log report info [disk image] [vmlinux] [kernel image] ci2-upstream-kcsan-gce KCSAN: data-race in __lru_add_drain_all / folio_add_lru
2025/06/14 01:19 upstream 02adc1490e6d 0e8da31f .config console log report info [disk image] [vmlinux] [kernel image] ci2-upstream-kcsan-gce KCSAN: data-race in __lru_add_drain_all / folio_add_lru
2025/06/13 02:25 upstream 27605c8c0f69 98683f8f .config console log report info [disk image] [vmlinux] [kernel image] ci2-upstream-kcsan-gce KCSAN: data-race in __lru_add_drain_all / folio_add_lru
2025/06/12 00:36 upstream 488ef3560196 98683f8f .config console log report info [disk image] [vmlinux] [kernel image] ci2-upstream-kcsan-gce KCSAN: data-race in __lru_add_drain_all / folio_add_lru
2025/06/11 02:37 upstream aef17cb3d3c4 5d7e17ca .config console log report info [disk image] [vmlinux] [kernel image] ci2-upstream-kcsan-gce KCSAN: data-race in __lru_add_drain_all / folio_add_lru
2025/06/10 11:29 upstream f09079bd04a9 4826c28e .config console log report info [disk image] [vmlinux] [kernel image] ci2-upstream-kcsan-gce KCSAN: data-race in __lru_add_drain_all / folio_add_lru
2025/06/09 14:23 upstream 19272b37aa4f 4826c28e .config console log report info [disk image] [vmlinux] [kernel image] ci2-upstream-kcsan-gce KCSAN: data-race in __lru_add_drain_all / folio_add_lru
2021/12/14 16:36 upstream 5472f14a3742 d018dd31 .config console log report info ci2-upstream-kcsan-gce KCSAN: data-race in __lru_add_drain_all / folio_add_lru
2021/11/02 13:42 upstream bfc484fe6abb 098b5d53 .config console log report info ci2-upstream-kcsan-gce KCSAN: data-race in __lru_add_drain_all / folio_add_lru
* Struck through repros no longer work on HEAD.