syzbot


WARNING in do_check

Status: upstream: reported C repro on 2025/06/13 07:12
Subsystems: bpf
[Documentation on labels]
Reported-by: syzbot+a36aac327960ff474804@syzkaller.appspotmail.com
Fix commit: bpf: handle jset (if a & b ...) as a jump in CFG computation
Patched on: [ci-upstream-bpf-next-kasan-gce ci-upstream-linux-next-kasan-gce-root ci-upstream-rust-kasan-gce], missing on: [ci-qemu-gce-upstream-auto ci-qemu-native-arm64-kvm ci-qemu-upstream ci-qemu-upstream-386 ci-qemu2-arm32 ci-qemu2-arm64 ci-qemu2-arm64-compat ci-qemu2-arm64-mte ci-qemu2-riscv64 ci-snapshot-upstream-root ci-upstream-bpf-kasan-gce ci-upstream-gce-arm64 ci-upstream-gce-leak ci-upstream-kasan-badwrites-root ci-upstream-kasan-gce ci-upstream-kasan-gce-386 ci-upstream-kasan-gce-root ci-upstream-kasan-gce-selinux-root ci-upstream-kasan-gce-smack-root ci-upstream-kmsan-gce-386-root ci-upstream-kmsan-gce-root ci-upstream-net-kasan-gce ci-upstream-net-this-kasan-gce ci2-upstream-fs ci2-upstream-kcsan-gce ci2-upstream-usb]
First crash: 25d, last: 1d13h
Cause bisection: failed (error log, bisect log)
  
Discussions (2)
Title Replies (including bot) Last reply
[PATCH bpf-next v1 1/2] bpf: handle jset (if a & b ...) as a jump in CFG computation 2 (2) 2025/06/13 19:10
[syzbot] [bpf?] WARNING in do_check 2 (3) 2025/06/13 16:10

Sample crash report:
------------[ cut here ]------------
verifier bug: add backedge: no SCC in verification path, insn_idx 9(1)
WARNING: CPU: 1 PID: 5838 at kernel/bpf/verifier.c:1970 add_scc_backedge kernel/bpf/verifier.c:1969 [inline]
WARNING: CPU: 1 PID: 5838 at kernel/bpf/verifier.c:1970 is_state_visited kernel/bpf/verifier.c:19417 [inline]
WARNING: CPU: 1 PID: 5838 at kernel/bpf/verifier.c:1970 do_check+0xda21/0xdba0 kernel/bpf/verifier.c:19861
Modules linked in:
CPU: 1 UID: 0 PID: 5838 Comm: syz-executor286 Not tainted 6.15.0-syzkaller-g1c66f4a3612c #0 PREEMPT(full) 
Hardware name: Google Google Compute Engine/Google Compute Engine, BIOS Google 05/07/2025
RIP: 0010:add_scc_backedge kernel/bpf/verifier.c:1969 [inline]
RIP: 0010:is_state_visited kernel/bpf/verifier.c:19417 [inline]
RIP: 0010:do_check+0xda21/0xdba0 kernel/bpf/verifier.c:19861
Code: 01 90 48 b8 00 00 00 00 00 fc ff df 41 0f b6 04 06 84 c0 0f 85 2b 01 00 00 41 8b 75 00 48 c7 c7 20 49 91 8b e8 d0 05 ad ff 90 <0f> 0b 90 90 e9 27 fe ff ff e8 11 5d e9 ff e8 3c 10 4d 00 ba 38 00
RSP: 0018:ffffc900043eeec0 EFLAGS: 00010246
RAX: 53f7659fb2f02200 RBX: ffffc900043ef180 RCX: ffff8880257d1e00
RDX: 0000000000000000 RSI: 0000000000000001 RDI: 0000000000000002
RBP: ffffc900043ef2c8 R08: 0000000000000003 R09: 0000000000000004
R10: dffffc0000000000 R11: fffffbfff1bfaa44 R12: ffff88801c7a4b00
R13: ffff88801c7a4b54 R14: 1ffff110038f496a R15: 0000000000000000
FS:  000055556bd6a380(0000) GS:ffff888125d54000(0000) knlGS:0000000000000000
CS:  0010 DS: 0000 ES: 0000 CR0: 0000000080050033
CR2: 000000000ebea398 CR3: 00000000713fa000 CR4: 00000000003526f0
DR0: 0000000000000000 DR1: 0000000000000000 DR2: 0000000000000000
DR3: 0000000000000000 DR6: 00000000fffe0ff0 DR7: 0000000000000400
Call Trace:
 <TASK>
 do_check_common+0x18fa/0x2460 kernel/bpf/verifier.c:23086
 do_check_main kernel/bpf/verifier.c:23177 [inline]
 bpf_check+0x110e2/0x1a240 kernel/bpf/verifier.c:24530
 bpf_prog_load+0x1318/0x1930 kernel/bpf/syscall.c:2972
 __sys_bpf+0x5f1/0x860 kernel/bpf/syscall.c:5978
 __do_sys_bpf kernel/bpf/syscall.c:6085 [inline]
 __se_sys_bpf kernel/bpf/syscall.c:6083 [inline]
 __x64_sys_bpf+0x7c/0x90 kernel/bpf/syscall.c:6083
 do_syscall_x64 arch/x86/entry/syscall_64.c:63 [inline]
 do_syscall_64+0xfa/0x3b0 arch/x86/entry/syscall_64.c:94
 entry_SYSCALL_64_after_hwframe+0x77/0x7f
RIP: 0033:0x7f37a741f569
Code: 48 83 c4 28 c3 e8 37 17 00 00 0f 1f 80 00 00 00 00 48 89 f8 48 89 f7 48 89 d6 48 89 ca 4d 89 c2 4d 89 c8 4c 8b 4c 24 08 0f 05 <48> 3d 01 f0 ff ff 73 01 c3 48 c7 c1 b8 ff ff ff f7 d8 64 89 01 48
RSP: 002b:00007ffe3011bf08 EFLAGS: 00000246 ORIG_RAX: 0000000000000141
RAX: ffffffffffffffda RBX: 00007ffe3011c0d8 RCX: 00007f37a741f569
RDX: 0000000000000094 RSI: 0000200000000840 RDI: 0000000000000005
RBP: 00007f37a7492610 R08: 00007ffe3011c0d8 R09: 00007ffe3011c0d8
R10: 0000000000000000 R11: 0000000000000246 R12: 0000000000000001
R13: 00007ffe3011c0c8 R14: 0000000000000001 R15: 0000000000000001
 </TASK>

Crashes (48):
Time Kernel Commit Syzkaller Config Log Report Syz repro C repro VM info Assets (help?) Manager Title
2025/06/12 17:33 bpf-next 1c66f4a3612c 98683f8f .config strace log report syz / log C [disk image] [vmlinux] [kernel image] ci-upstream-bpf-next-kasan-gce WARNING in do_check
2025/06/12 17:00 bpf-next 1c66f4a3612c 98683f8f .config strace log report syz / log C [disk image] [vmlinux] [kernel image] ci-upstream-bpf-next-kasan-gce WARNING in do_check
2025/06/12 15:11 bpf-next 1c66f4a3612c 98683f8f .config strace log report syz / log C [disk image] [vmlinux] [kernel image] ci-upstream-bpf-next-kasan-gce WARNING in do_check
2025/06/12 13:53 bpf-next 1c66f4a3612c 98683f8f .config console log report info [disk image] [vmlinux] [kernel image] ci-upstream-bpf-next-kasan-gce WARNING in do_check
2025/06/12 13:53 bpf-next 1c66f4a3612c 98683f8f .config console log report info [disk image] [vmlinux] [kernel image] ci-upstream-bpf-next-kasan-gce WARNING in do_check
2025/06/12 13:44 bpf-next 1c66f4a3612c 98683f8f .config console log report info [disk image] [vmlinux] [kernel image] ci-upstream-bpf-next-kasan-gce WARNING in do_check
2025/06/12 13:44 bpf-next 1c66f4a3612c 98683f8f .config console log report info [disk image] [vmlinux] [kernel image] ci-upstream-bpf-next-kasan-gce WARNING in do_check
2025/06/12 12:51 bpf-next 1c66f4a3612c 98683f8f .config console log report info [disk image] [vmlinux] [kernel image] ci-upstream-bpf-next-kasan-gce WARNING in do_check
2025/06/12 12:51 bpf-next 1c66f4a3612c 98683f8f .config console log report info [disk image] [vmlinux] [kernel image] ci-upstream-bpf-next-kasan-gce WARNING in do_check
2025/06/12 12:51 bpf-next 1c66f4a3612c 98683f8f .config console log report info [disk image] [vmlinux] [kernel image] ci-upstream-bpf-next-kasan-gce WARNING in do_check
2025/06/12 12:51 bpf-next 1c66f4a3612c 98683f8f .config console log report info [disk image] [vmlinux] [kernel image] ci-upstream-bpf-next-kasan-gce WARNING in do_check
2025/07/05 23:46 linux-next 26ffb3d6f02c 4f67c4ae .config console log report info [disk image] [vmlinux] [kernel image] ci-upstream-linux-next-kasan-gce-root WARNING in do_check
2025/06/30 00:40 linux-next 2aeda9592360 fc9d8ee5 .config console log report info [disk image] [vmlinux] [kernel image] ci-upstream-linux-next-kasan-gce-root WARNING in do_check
2025/06/25 05:26 linux-next 2ae2aaafb214 26d77996 .config console log report info [disk image] [vmlinux] [kernel image] ci-upstream-linux-next-kasan-gce-root WARNING in do_check
2025/06/24 23:49 linux-next 2ae2aaafb214 26d77996 .config console log report info [disk image] [vmlinux] [kernel image] ci-upstream-linux-next-kasan-gce-root WARNING in do_check
2025/06/24 23:48 linux-next 2ae2aaafb214 26d77996 .config console log report info [disk image] [vmlinux] [kernel image] ci-upstream-linux-next-kasan-gce-root WARNING in do_check
2025/06/24 21:29 linux-next 2ae2aaafb214 26d77996 .config console log report info [disk image] [vmlinux] [kernel image] ci-upstream-linux-next-kasan-gce-root WARNING in do_check
2025/06/24 21:28 linux-next 2ae2aaafb214 26d77996 .config console log report info [disk image] [vmlinux] [kernel image] ci-upstream-linux-next-kasan-gce-root WARNING in do_check
2025/06/24 19:51 linux-next 2ae2aaafb214 26d77996 .config console log report info [disk image] [vmlinux] [kernel image] ci-upstream-linux-next-kasan-gce-root WARNING in do_check
2025/06/24 19:51 linux-next 2ae2aaafb214 26d77996 .config console log report info [disk image] [vmlinux] [kernel image] ci-upstream-linux-next-kasan-gce-root WARNING in do_check
2025/06/24 19:49 linux-next 2ae2aaafb214 26d77996 .config console log report info [disk image] [vmlinux] [kernel image] ci-upstream-linux-next-kasan-gce-root WARNING in do_check
2025/06/24 19:37 linux-next 2ae2aaafb214 26d77996 .config console log report info [disk image] [vmlinux] [kernel image] ci-upstream-linux-next-kasan-gce-root WARNING in do_check
2025/06/24 19:37 linux-next 2ae2aaafb214 26d77996 .config console log report info [disk image] [vmlinux] [kernel image] ci-upstream-linux-next-kasan-gce-root WARNING in do_check
2025/06/22 10:09 linux-next 5d4809e25903 d6cdfb8a .config console log report info [disk image] [vmlinux] [kernel image] ci-upstream-linux-next-kasan-gce-root WARNING in do_check
2025/06/22 10:09 linux-next 5d4809e25903 d6cdfb8a .config console log report info [disk image] [vmlinux] [kernel image] ci-upstream-linux-next-kasan-gce-root WARNING in do_check
2025/06/15 10:35 linux-next bc6e0ba6c9ba 5f4b362d .config console log report info [disk image] [vmlinux] [kernel image] ci-upstream-linux-next-kasan-gce-root WARNING in do_check
2025/06/13 09:42 linux-next bc6e0ba6c9ba 98683f8f .config console log report info [disk image] [vmlinux] [kernel image] ci-upstream-linux-next-kasan-gce-root WARNING in do_check
2025/06/13 09:42 linux-next bc6e0ba6c9ba 98683f8f .config console log report info [disk image] [vmlinux] [kernel image] ci-upstream-linux-next-kasan-gce-root WARNING in do_check
2025/06/13 09:10 linux-next bc6e0ba6c9ba 98683f8f .config console log report info [disk image] [vmlinux] [kernel image] ci-upstream-linux-next-kasan-gce-root WARNING in do_check
2025/06/13 09:09 linux-next bc6e0ba6c9ba 98683f8f .config console log report info [disk image] [vmlinux] [kernel image] ci-upstream-linux-next-kasan-gce-root WARNING in do_check
2025/06/13 07:16 linux-next bc6e0ba6c9ba 98683f8f .config console log report info [disk image] [vmlinux] [kernel image] ci-upstream-linux-next-kasan-gce-root WARNING in do_check
2025/06/13 07:15 linux-next bc6e0ba6c9ba 98683f8f .config console log report info [disk image] [vmlinux] [kernel image] ci-upstream-linux-next-kasan-gce-root WARNING in do_check
2025/06/13 07:11 linux-next bc6e0ba6c9ba 98683f8f .config console log report info [disk image] [vmlinux] [kernel image] ci-upstream-linux-next-kasan-gce-root WARNING in do_check
2025/06/13 07:10 linux-next bc6e0ba6c9ba 98683f8f .config console log report info [disk image] [vmlinux] [kernel image] ci-upstream-linux-next-kasan-gce-root WARNING in do_check
2025/06/13 03:22 linux-next 0bb71d301869 98683f8f .config console log report info [disk image] [vmlinux] [kernel image] ci-upstream-linux-next-kasan-gce-root WARNING in do_check
2025/06/13 03:22 linux-next 0bb71d301869 98683f8f .config console log report info [disk image] [vmlinux] [kernel image] ci-upstream-linux-next-kasan-gce-root WARNING in do_check
2025/06/12 21:56 linux-next 0bb71d301869 98683f8f .config console log report info [disk image] [vmlinux] [kernel image] ci-upstream-linux-next-kasan-gce-root WARNING in do_check
2025/06/12 21:56 linux-next 0bb71d301869 98683f8f .config console log report info [disk image] [vmlinux] [kernel image] ci-upstream-linux-next-kasan-gce-root WARNING in do_check
2025/06/12 21:56 linux-next 0bb71d301869 98683f8f .config console log report info [disk image] [vmlinux] [kernel image] ci-upstream-linux-next-kasan-gce-root WARNING in do_check
2025/06/12 21:56 linux-next 0bb71d301869 98683f8f .config console log report info [disk image] [vmlinux] [kernel image] ci-upstream-linux-next-kasan-gce-root WARNING in do_check
2025/06/12 21:56 linux-next 0bb71d301869 98683f8f .config console log report info [disk image] [vmlinux] [kernel image] ci-upstream-linux-next-kasan-gce-root WARNING in do_check
2025/06/12 21:56 linux-next 0bb71d301869 98683f8f .config console log report info [disk image] [vmlinux] [kernel image] ci-upstream-linux-next-kasan-gce-root WARNING in do_check
2025/06/12 21:55 linux-next 0bb71d301869 98683f8f .config console log report info [disk image] [vmlinux] [kernel image] ci-upstream-linux-next-kasan-gce-root WARNING in do_check
* Struck through repros no longer work on HEAD.